<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-28 18-32-32
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 57 dBuV SANDELS
Pilot RDS Phase Difference
6.6 kHz 5.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
15 kHz 60 kHz 14551 7,0236
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 2,25 dBr 2,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 9 --:--
RT
-
AF EON
92.0, 94.7, 98.5, 106.3, 107.5 MHz -
FM Scope Max at: 60 kHz MIN: 15 kHz % above 76 kHz: 7,0236 Acquired: 2024/08/28 18.31.28 Total samples: 14551 Equivalent time: 0:12:07 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 2,9 dBr MIN: 0,8 dBr AVE: 2,25 dBr % above 12,2 dBr: 0,0 Last value: 2,6 dBr (2024/08/28 18.31.28) 18.18 18.20 18.22 18.24 18.26 18.28 18.30 -1 0 1 2 3 Pm [dBr]